Yukon Choice PC – World’s Longest Studied Coronary Drug Eluting Stent

  • Yukon Choice PC is a Biodegradable Polymer Coronary Drug Eluting Stent. The Drug is Sirolimus which is a well-studied and clinically proven immunosuppressant.
  • The Stent platform is of Stainless Steel with Microporous Stent Surface. The patented technology of micro pores acts like reservoirs for delivering the drug to the targeted site. Micro pores use vander-wall forces for the controlled released of drug. Microporous surface also reduce the polymer load to 1/4th.
  • The Dual drug matrix is coated on the Abluminal side which ensures better Endothelialization and less systemic exposure of the drug.
  • Shellac Resin is the top coat of the stent for smooth surface which prevents dual drug matrix break ups during stent expansion.
  • Yukon Choice PC is one of the longest studied DES with 10 years of data establishing its safety and efficacy published in Circulation 

Product Matrix/ Ordering Information

Stent Diameter Ø  (mm)

Stent length (mm) & Article number

8

12

16

18

21

24

28

32

Ø2.00

YCPC2008

YCPC2012

YCPC2016

YCPC2018

YCPC2021

YCPC2024

YCPC2088

YCPC2032

Ø2.25

YCPC2208

YCPC2212

YCPC2216

YCPC2218

YCPC2221

YCPC2224

YCPC2228

YCPC2232

Ø2.50

YCPC2508

YCPC2512

YCPC2516

YCPC2518

YCPC2521

YCPC2524

YCPC2528

YCPC2532



Stent Diameter Ø (mm)

Stent length (mm) & Article number

8

12

16

18

21

24

28

32

36

40

Ø2.75

YCPC2708

YCPC2712

YCPC2716

YCPC2718

YCPC2721

YCPC2724

YCPC2728

YCPC2732

YCPC2736

YCPC2740

Ø3.00

YCPC3008

YCPC3012

YCPC3016

YCPC3018

YCPC3021

YCPC3024

YCPC3028

YCPC3032

YCPC3036

YCPC3040

Ø 3.50

YCPC3508

YCPC3512

YCPC3516

YCPC3518

YCPC3521

YCPC3524

YCPC3528

YCPC3532

YCPC3536

YCPC3540

Ø 4.00

YCPC4008

YCPC4012

YCPC4016

YCPC4018

YCPC4020

YCPC4024

YCPC4028

YCPC4032

YCPC4036

YCPC4040

Compliance Chart

Balloon Ø (mm)

Inflation pressure (bar/105 Pa

 

NP

 

 

 

 

 

 

RBP

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Ø 2.00

1.90

1.94

1.97

2.00

2.03

2.07

2.10

2.13

2.17

2.20

2.23

2.27

2.32

2.38

2.41

Ø 2.25

2.15

2.18

2.47

2.25

2.28

2.32

2.35

2.38

2.42

2.45

2.49

2.52

2.55

2.59

2.62

Ø 2.50

2.40

2.43

2.21

2.50

2.54

2.57

2.64

2.57

2.67

2.71

2.74

2.77

2.81

2.84

2.88

Ø 2.75

2.65

2.68

2.72

2.75

2.78

2.82

2.88

2.81

2.92

2.95

2.98

3.01

3.28

3.31

3.34

Ø 3.00

2.89

2.93

2.97

3.00

3.04

3.08

3.15

3.07

3.19

3.23

3.26

3.22

3.34

3.37

3.41

Ø 3.50

3.37

3.42

3.46

3.50

3.54

3.58

3.67

3.59

3.71

3.75

3.79

3.84

3.88

3.92

3.96

Ø 4.00

3.85

3.90

3.96

4.00

4.05

4.10

4.21

4.11

4.26

4.31

4.36

4.41

4.46

4.51

4.56

 Technical Data

Crossing Profile (Ø 2.5 mm)

0.035’’/0.89 mm

Strut Thickness (Ø 2.5 mm)

0.0034’’/87µm

Metallic Surface Area

16-18%

No Foreshortening

 

Balloon Marker Material

Platinum/ Iridium

Entry Profile

0.016’’/0.41 mm

Proximal Shaft Diameter

1.9 F

Distal Shaft Diameter

2.4 F

Recommended Guide Wire

0.014’’

Guiding Catheter

Min. 5 F